<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-06 12-40-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.10 MHz 3/5, 41 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
4 kHz 68 kHz 2102 11,8934
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,7 dBr 8,02 dBr 8,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 1 12:40, 6.01.2025
RT
-
AF EON
87.6, 87.7, 90.2, 90.4, 90.6, 92.3, 95.3, 96.4, 97.3, 99.1, 100.7, 101.2, 101.6, 102.6, 103.1, 103.2, 103.3, 103.6, 104.1, 104.8, 106.7, 107.2, 107.3, 107.5, 107.9 MHz -
FM Scope Station: 103.10 MHz, signal: 2/5 (43 dBuV) Max at: 68 kHz MIN: 4 kHz % above 75 kHz: 11,8934 Acquired: 2025/01/06 12:39:44 Total samples: 2102 Equivalent time: 0:01:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100
FM Scope MAX: 8,4 dBr MIN: 7,7 dBr AVE: 8,02 dBr % above 10,0 dBr: 0,0 Last value: 7,7 dBr (2025/01/06 12:39:43) Station: 103.10 MHz, signal: 3/5 (42 dBuV) 12:33 12:34 12:35 12:36 12:37 12:38 12:39 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality